PRODUCT
We specialize in water pump controller and accessories production.
H131
The Pump Controller is a programmable control panel that is used to protect and control pumps.
Category:
Product Details
The Pump Controller is a programmable control panel that is used to protect and control pumps. Primarily deep well submersible pumps, but also centrifugal; in-line; circulation and multistage pumps. The Controller has max 7 general operating modes, namely tank to tank; booster by pressure switch; drainage by sensor etc. The Controller’s protection features are dry run; overload; stalled pump; over voltage; under voltage; open phase, phase reversal and thermal control.
* :only plus controller have these terminals
BUTTON &OPERATIONS
|
BUTTON |
OPERATION [MANUAL mode unless otherwise stipulated] |
|
START |
Pump should start if not running. |
|
STOP |
Pump should stop if running. |
|
STOP then MODE |
Display shows last five failure records |
|
STOP then START |
Display shows accumulative running time |
|
MODE SET |
[ Parameter 009 set to 00]- Manual to Auto/ Auto to Manual [ Parameter 009 set to 01]- All buttons locked in Auto mode, To deactivate hold "MODE" for 5sec.pump will then stop, and controller will switch to manual mode. |
|
To ensure pump and motor is protected it is essential to calibrate the controller parameters as soon as the pump is running to operational standards. Perform calibration after each installation or maintenance operation. |
|
|
START |
Parameter calibration: In Manual mode press“START", give the pump time to run as it would normally then hold "START"(approximately 5-10 sec) or press the“STORE" button (Button on mainboard with yellow cap). The controller will make a“Di”sound. The controller should now be calibrated to the current spec of the motor. |
|
STOP |
Parameter erasing: Ensure pump has stopped running then hold “STOP” until the controller makes a “Di” sound. (Hold for approximately 5-10 sec). The controller should now be cleared of all calibrations |
SPECIFICATIONS
|
Main technical characteristics of controller |
||
|
Control functions |
Double liquid level control |
|
|
Pressure switch control |
||
|
Temperature control. |
||
|
Main technical data |
||
|
Rated output power |
Refer to label on controller |
|
|
Rated input voltage |
Refer to label on controller |
|
|
Liquid level transfer distance |
≤200m |
|
|
Protection function |
Dry run |
Pump stall |
|
Overload |
Open phase |
|
|
Under/Over voltage |
Phase reversal |
|
|
Main installation data |
||
|
Working temperature |
-25°C – +55°C |
|
|
Working humidity |
20% - 90% Relative Humidity |
|
|
Degree of protection |
IP65 |
|
|
Installation position |
Vertical |
|
|
Unit dimensions (Lx W x H) |
330*250*135mm |
|
TROUBLE SHOOTING GUIDE

Consult Now